| ID | Description |
|---|---|
| 37395 | In some rare racy conditions a server may remain stuck in a deleting state. |
| 37205 | Incorrect handling of IO errors from NVMe SSDs during abrupt recovery may cause node recovery to fail. |
| 37114 | In releases 3.13.1 and 3.14.1, the node-manager could fail to start, causing a Lightbits node to fail to come up. This can occur when the following conditions are all true:
|
| 36882 | GFTL service could fail locally due to a rare race condition when a SSD failure/removal, a SSD read submission, and multiple volume rebuilds all occur at exactly the same time. |
| 36722 | Users can reference the NVMe device by its path name (e.g., /dev/nvme0n1) - as used during the initial system setup - to determine the storage SSD used by servers in the Lightbits storage cluster. However, this could lead to data loss since device names are not persistent across reboots. |
| 36282 |
|
Was this page helpful?